ASTM D6413

AMERICAN REQUIREMENTS FOR FABRIC RESISTANCE WHEN PRESENTED WITH VERTICAL FLAME

ASTM D6413 – This standard specifies the protection levels that garments and fabric must meet when presented with fire upon a vertical flame test.

REQUIREMENTS FOR ASTM D6413 STANDARD CERTIFICATION

TEST METHOD
DESCRIPTION
MINIMUM COMPLIANCE VALUES

ASTM D6413

Each individual layer of the group must be tested separately.
Fabric tags specifying that they must be washed must be tested before and after 100 wash and dry cycles.
The flame exposure time is 12 seconds.
After flame exposure and allowing the fabric to cool, the appropriate weight must be hung to provide the sufficient tear force.

Both the fabric and the reflective tapes used in flame resistant garments must have a charred length of less than or equal to 100 mm (4 inches) as well as a post-incandescence of no more than 2 seconds. The fabric cannot drip or melt. The gas used must be methane.

Tearing force for carbonization length determination
Base weight of the fabricTotal tear force
g/m²oz/yd²goz
68 a 2032.0 a 6.01004.0
más de 203 a 508más de 6.0 a 15.02008.0
more than 508 a 780more than 15.0 a 23.030012.0
more than 780more than 23.047516.0

The base weight of the fabric refers to the weight of the fabric before adding any fireproof or coating treatments

Sectors where the ASTM D6413 standard is applicable

FIREFIGHTERS

FOREST FIREFIGHTERS

GAS INDUSTRY

CHEMICAL INDUSTRY

some of the Marina Textil fabrics that comply with the ASTM D6413 standard

If you have any questions, please contact our technical department experts.

MARLANPLUS 235

Descargar ficha técnica