EN ISO 15025

FABRIC BEHAVIOUR WHEN PRESENTED WITH A FLAME

The EN ISO 15025 test method analyses limited flame spread on fabrics.

EN ISO 15025 TEST METHOD REQUIREMENTS

TEST METHOD

DESCRIPTION

MINIMUM COMPLIANCE VALUES

EN ISO 15025

Procedure A:
superficial ignition → the burner is placed perpendicular to the fabric surface. Flame is applied for 10 seconds and the following information is observed and recorded:

a) whether the flame reaches the upper border or any border of the sample
b) post-combustion time
c) post-incandescence time
d) if post-incandescence spreads beyond the ignited area
e) peeling of residues
f) whether the residues ignite the filter paper
g) whether a hole forms and in which layer

Procedure B:
Border ignition → the burner is placed in a 30° angle with respect to the vertical axis. The distance between the edge of the burner and the lower border of the fabric must be 20 mm ± 2 mm. The flame is applied for 10 seconds and the previous information should be observed and recorded, except for g).

Sectors where the test method EN ISO 15025 is applied

IRON FOUNDRY

COOPER FOUNDRY

ALUMINUM FOUNDRY

ZINC FOUNDRY

GLASS FOUNDRY

CEMENT PLANTS

ELECTRIC COMPANIES

GAS INDUSTRY

CHEMICAL INDUSTRY

UTILITIES AND SUBCONTRACTORS

RENEWABLE ENERGY

FIREFIGHTERS

FOREST FIREFIGHTERS

POLICE AND MILITARY

WELDING

SHIPBUILDING

CATENARIES

INDUSTRIAL LAUNDRIES

OIL PLATFORMS

AUTOMOTIVES

Some Marina Textil fabrics that comply with the test method EN ISO 15025

If you have any questions, please contact our technical department experts.

MARLANPLUS 235